AMFLO® SONIC UFA 340
Medium
- Thermal energy
Product Categories
- Measure
Processes
- Measure
Application
- Flow meter
- Building services engineering
- Local and district heating / district cooling
Countries
- Germany
- Switzerland
- Singapore
- Other countries
Features / Benefits
- Versatile — Measures various liquids without the need for recalibration
- Maximum durability — no wear parts, backward-compatible sensor design
- Easy installation — no grounding rings, grounding cables, or current rectifiers required
- Advanced diagnostic functions (NAMUR NE 107) for predictive maintenance
- Suitable for extreme conditions: cryogenic (-200 °C) to extended temperature range (+250 °C), high viscosity up to 1000 cSt
Technical data
- Design: 3 parallel sound paths, fully welded
- Nominal diameter range: DN25…3000 / 1…120 inches
- Materials (in contact with media): Steel, stainless steel (others available upon request)
- Power supply: 85–250 VAC; 11–31 VDC; 20.5–26 VAC/DC
- Inputs/Outputs: Current (including HART 7), Pulse, Frequency, and/or Status Output, Limit Switch/Control Input
- Communication Interfaces: Modbus RS485
- Diagnostic Functions: VDI NAMUR NE 107
- Certifications for potentially explosive atmospheres: ATEX, IEC-Ex, cCSAus, NEPSI
- Medieneigenschaften: einphasige Flüssigkeit, <5 % Feststoffanteil, <2 % Gasanteil, max. 100 cSt (Standard)
- High-viscosity option: up to 1,000 cSt
- Ambient temperature: -40…+65 °C / -40…+149 °F
- Process temperature: -45…+250 °C (depending on the version, up to -200 °C for cryogenic applications)
- Process connections: EN 1092-1 PN 6…100; ASME B16.5 150…900 lbs
- Measurement range: v = 0.3…20 m/s (bidirectional)
- Accuracy / Repeatability: ±0.3% of the measured value ±2 mm/s / 0.2%
Downloads
Technical data sheets
Installation guide and user manual
Request a quote
Your inquiry regarding:
AMFLO® SONIC UFA 340