Thermal energy solutions

Our thermal energy portfolio offers solutions for all your requirements. These are characterised by low starting values, high measuring dynamics and outstanding precision. It is even possible to cover extensive temperature ranges right through to refrigeration networks. We furthermore offer recalibration without process interruption. Thanks to the many different communication options, integration into data collection systems is extremely simple and our focus in this regard is on minimising your total cost of ownership.

Measure

Measuring solutions for thermal energy applications

tech preview
  • DN25…1200, PN16
  • TFluid = -20 – 150 °C (depending on coating type)
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Pro

Electromagnetic flowmeter for measuring energy
in industrial and commercial buildings

tech preview
  • DN 20 – 40
  • PN 40 (flange); PN 16 (thread)
  • TFluid = 1 – 130 °C / TAmb = 5 – 55 °C
  • Measuring tube made of stainless steel (type 1.4404/316(L)) Stainless steel flange (type 1.4307/304L or 1.4404/316)
  • Approval according to MID 2014/32/EU

AMFLO® SONIC Smart

Ultrasonic flowmeter with integrated electronics for district heating and building automation

tech preview
  • DN 32 – 250
  • PN 16/25/40
  • TFluid = 1 – 130 °C / TAmb = 5 – 55 °C
  • Stainless steel measuring tube type 1.4404/316(L)
  • Approval according to MID 2004/22/EG (EN1434) and PTB TR K7.2 (Cold)

AMFLO® SONIC DryX

Ultrasonic flowmeter with an innovative replacement concept –
Extremely beneficial for district heating

tech preview
  • DN 15 – 100
  • TFluid = 1 – 60 °C / TAmb = 5 – 55 °C (water or glycol water)
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Smart

Compact magnetic flowmeter
in industrial and commercial buildings

tech preview
  • DN 50 – 1200
  • No moving parts in the measuring tube
  • TFluid = 2 – 120°C (180 °C), TAmb = 0 – 60°C
  • Approvals according to EN 1434

AMFLO® SONIC UFA-280

Ultrasonic flowmeter for district heating and building automation

tech preview
  • DN 15 – 100
  • PN 16 (versions with thread); PN 25 (version with flanges)
  • Approval according to MID 2004/22/EG (EN1434)
  • TFluid = 5 – 130/150 °C / TAmb = 5 – 55 °C
  • Measuring pipe in steel brass (DN 15 – 40) and grey steel (DN 50 – 100)

AMFLO® SONIC UFA-113

Compact ultrasonic flowmeter with integrated electronics for district heating and building automatisation

tech preview
  • DN15 – 100
  • TFluid = 5 – 130/150 °C / TAmb = 5 – 50 °C
  • Homologations according to EN1434 and MID class 2 and 3
  • Measuring pipe in steel brass (DN 15 – 40) and grey steel (DN 50 – 100)

AMTRON® SONIC D

Compact energy meter for building automation

tech preview
  • For energy measurement in heating and/or air-conditioning systems
  • 10+1 year battery power (replaceable)
  • Installation as desired (vertical/horizontal)
  • Metrological approval according to 2014/32/EU (MID) and PTB K 7.2
  • With M-Bus interface or wireless M-Bus (radio) interface according to WHO standard

AMTRON® S3 / S3+

Compact energy meter for apartments

tech preview
  • For energy measurement in heating and/or air-conditioning systems
  • 10+1 year battery power (replaceable)
  • Installation as desired (vertical/horizontal)
  • Metrological approval according to 2014/32/EU (MID) and PTB K 7.2
  • With M-Bus interface or wireless M-Bus (radio) interface according to WHO standard

AMTRON® S3U

Compact energy meter for apartments

tech preview
  • Plug-in computer module
  • Interfaces to building management systems: M-Bus, LON, Modbus, N2Open, BACnet MS/TP, KNX
  • Sliding data for standard refrigerants
  • Integrated power supply for flowmeters
  • Metrological approval according to 2014/32/EU (MID) and PTB K7.2 (cold, hot/cold combined)

CALEC® ST II

Multi-functional thermal energy calculator for district heating and building technology

tech preview
  • Multi-function display with plain text and selectable language (D, E, F, I)
  • Medium temperature -50…550°C (approval 1…200°C)
  • Temperature difference 0…190K (approval 3…199K)
  • Integrated power supply for flowmeters
  • Metrological approval according to 2014/32/EU (MID) and PTB K7.2 (cold, hot/cold combined)

CALEC® energy master

Multi functional thermal energy calculator for district heating and building technology

tech preview
  • Pt100 sensors
  • DIN head for 4-wire connection
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors PLH

4-wire DIN head temperature sensors for pocket mounting

tech preview
  • Pt100 or Pt500 sensors
  • 2-wire connection with 2.5 m fixed cable
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors PLC

2-wire cable temperature sensors for pocket mounting

tech preview
  • Pt100 or Pt500 sensors
  • 2-wire connection with 2.5 m fixed cable
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors DS/PSC

2-wire cable temperature sensors for direct immersion or immersion in a thermowell

tech preview
  • DN125…250, PN16
  • TFluid = 0 – 80 °C
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Basic

Electromagnetic compact flowmeter with integrated electronics for energy measurement
in industrial and commercial buildings

tech preview
  • DN25…1200, PN16
  • TFluid = -20 – 150 °C (depending on coating type)
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Pro

Electromagnetic flowmeter for measuring energy
in industrial and commercial buildings

tech preview
  • DN 20 – 40
  • PN 40 (flange); PN 16 (thread)
  • TFluid = 1 – 130 °C / TAmb = 5 – 55 °C
  • Measuring tube made of stainless steel (type 1.4404/316(L)) Stainless steel flange (type 1.4307/304L or 1.4404/316)
  • Approval according to MID 2014/32/EU

AMFLO® SONIC Smart

Ultrasonic flowmeter with integrated electronics for district heating and building automation

tech preview
  • DN 32 – 250
  • PN 16/25/40
  • TFluid = 1 – 130 °C / TAmb = 5 – 55 °C
  • Stainless steel measuring tube type 1.4404/316(L)
  • Approval according to MID 2004/22/EG (EN1434) and PTB TR K7.2 (Cold)

AMFLO® SONIC DryX

Ultrasonic flowmeter with an innovative replacement concept –
Extremely beneficial for district heating

tech preview
  • DN 15 – 100
  • TFluid = 1 – 60 °C / TAmb = 5 – 55 °C (water or glycol water)
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Smart

Compact magnetic flowmeter
in industrial and commercial buildings

tech preview
  • DN 50 – 1200
  • No moving parts in the measuring tube
  • TFluid = 2 – 120°C (180 °C), TAmb = 0 – 60°C
  • Approvals according to EN 1434

AMFLO® SONIC UFA-280

Ultrasonic flowmeter for district heating and building automation

tech preview
  • DN 15 – 100
  • PN 16 (versions with thread); PN 25 (version with flanges)
  • Approval according to MID 2004/22/EG (EN1434)
  • TFluid = 5 – 130/150 °C / TAmb = 5 – 55 °C
  • Measuring pipe in steel brass (DN 15 – 40) and grey steel (DN 50 – 100)

AMFLO® SONIC UFA-113

Compact ultrasonic flowmeter with integrated electronics for district heating and building automatisation

tech preview
  • DN15 – 100
  • TFluid = 5 – 130/150 °C / TAmb = 5 – 50 °C
  • Homologations according to EN1434 and MID class 2 and 3
  • Measuring pipe in steel brass (DN 15 – 40) and grey steel (DN 50 – 100)

AMTRON® SONIC D

Compact energy meter for building automation

tech preview
  • For energy measurement in heating and/or air-conditioning systems
  • 10+1 year battery power (replaceable)
  • Installation as desired (vertical/horizontal)
  • Metrological approval according to 2014/32/EU (MID) and PTB K 7.2
  • With M-Bus interface or wireless M-Bus (radio) interface according to WHO standard

AMTRON® S3 / S3+

Compact energy meter for apartments

tech preview
  • For energy measurement in heating and/or air-conditioning systems
  • 10+1 year battery power (replaceable)
  • Installation as desired (vertical/horizontal)
  • Metrological approval according to 2014/32/EU (MID) and PTB K 7.2
  • With M-Bus interface or wireless M-Bus (radio) interface according to WHO standard

AMTRON® S3U

Compact energy meter for apartments

tech preview
  • Plug-in computer module
  • Interfaces to building management systems: M-Bus, LON, Modbus, N2Open, BACnet MS/TP, KNX
  • Sliding data for standard refrigerants
  • Integrated power supply for flowmeters
  • Metrological approval according to 2014/32/EU (MID) and PTB K7.2 (cold, hot/cold combined)

CALEC® ST II

Multi-functional thermal energy calculator for district heating and building technology

tech preview
  • Multi-function display with plain text and selectable language (D, E, F, I)
  • Medium temperature -50…550°C (approval 1…200°C)
  • Temperature difference 0…190K (approval 3…199K)
  • Integrated power supply for flowmeters
  • Metrological approval according to 2014/32/EU (MID) and PTB K7.2 (cold, hot/cold combined)

CALEC® energy master

Multi functional thermal energy calculator for district heating and building technology

tech preview
  • Pt100 sensors
  • DIN head for 4-wire connection
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors PLH

4-wire DIN head temperature sensors for pocket mounting

tech preview
  • Pt100 or Pt500 sensors
  • 2-wire connection with 2.5 m fixed cable
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors PLC

2-wire cable temperature sensors for pocket mounting

tech preview
  • Pt100 or Pt500 sensors
  • 2-wire connection with 2.5 m fixed cable
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors DS/PSC

2-wire cable temperature sensors for direct immersion or immersion in a thermowell

tech preview
  • DN125…250, PN16
  • TFluid = 0 – 80 °C
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Basic

Electromagnetic compact flowmeter with integrated electronics for energy measurement
in industrial and commercial buildings

tech preview
  • DN25…1200, PN16
  • TFluid = -20 – 150 °C (depending on coating type)
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Pro

Electromagnetic flowmeter for measuring energy
in industrial and commercial buildings

tech preview
  • DN 20 – 40
  • PN 40 (flange); PN 16 (thread)
  • TFluid = 1 – 130 °C / TAmb = 5 – 55 °C
  • Measuring tube made of stainless steel (type 1.4404/316(L)) Stainless steel flange (type 1.4307/304L or 1.4404/316)
  • Approval according to MID 2014/32/EU

AMFLO® SONIC Smart

Ultrasonic flowmeter with integrated electronics for district heating and building automation

tech preview
  • DN 32 – 250
  • PN 16/25/40
  • TFluid = 1 – 130 °C / TAmb = 5 – 55 °C
  • Stainless steel measuring tube type 1.4404/316(L)
  • Approval according to MID 2004/22/EG (EN1434) and PTB TR K7.2 (Cold)

AMFLO® SONIC DryX

Ultrasonic flowmeter with an innovative replacement concept –
Extremely beneficial for district heating

tech preview
  • DN 15 – 100
  • TFluid = 1 – 60 °C / TAmb = 5 – 55 °C (water or glycol water)
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Smart

Compact magnetic flowmeter
in industrial and commercial buildings

tech preview
  • DN 50 – 1200
  • No moving parts in the measuring tube
  • TFluid = 2 – 120°C (180 °C), TAmb = 0 – 60°C
  • Approvals according to EN 1434

AMFLO® SONIC UFA-280

Ultrasonic flowmeter for district heating and building automation

tech preview
  • DN 15 – 100
  • PN 16 (versions with thread); PN 25 (version with flanges)
  • Approval according to MID 2004/22/EG (EN1434)
  • TFluid = 5 – 130/150 °C / TAmb = 5 – 55 °C
  • Measuring pipe in steel brass (DN 15 – 40) and grey steel (DN 50 – 100)

AMFLO® SONIC UFA-113

Compact ultrasonic flowmeter with integrated electronics for district heating and building automatisation

tech preview
  • DN15 – 100
  • TFluid = 5 – 130/150 °C / TAmb = 5 – 50 °C
  • Homologations according to EN1434 and MID class 2 and 3
  • Measuring pipe in steel brass (DN 15 – 40) and grey steel (DN 50 – 100)

AMTRON® SONIC D

Compact energy meter for building automation

tech preview
  • For energy measurement in heating and/or air-conditioning systems
  • 10+1 year battery power (replaceable)
  • Installation as desired (vertical/horizontal)
  • Metrological approval according to 2014/32/EU (MID) and PTB K 7.2
  • With M-Bus interface or wireless M-Bus (radio) interface according to WHO standard

AMTRON® S3 / S3+

Compact energy meter for apartments

tech preview
  • For energy measurement in heating and/or air-conditioning systems
  • 10+1 year battery power (replaceable)
  • Installation as desired (vertical/horizontal)
  • Metrological approval according to 2014/32/EU (MID) and PTB K 7.2
  • With M-Bus interface or wireless M-Bus (radio) interface according to WHO standard

AMTRON® S3U

Compact energy meter for apartments

tech preview
  • Plug-in computer module
  • Interfaces to building management systems: M-Bus, LON, Modbus, N2Open, BACnet MS/TP, KNX
  • Sliding data for standard refrigerants
  • Integrated power supply for flowmeters
  • Metrological approval according to 2014/32/EU (MID) and PTB K7.2 (cold, hot/cold combined)

CALEC® ST II

Multi-functional thermal energy calculator for district heating and building technology

tech preview
  • Multi-function display with plain text and selectable language (D, E, F, I)
  • Medium temperature -50…550°C (approval 1…200°C)
  • Temperature difference 0…190K (approval 3…199K)
  • Integrated power supply for flowmeters
  • Metrological approval according to 2014/32/EU (MID) and PTB K7.2 (cold, hot/cold combined)

CALEC® energy master

Multi functional thermal energy calculator for district heating and building technology

tech preview
  • Pt100 sensors
  • DIN head for 4-wire connection
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors PLH

4-wire DIN head temperature sensors for pocket mounting

tech preview
  • Pt100 or Pt500 sensors
  • 2-wire connection with 2.5 m fixed cable
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors PLC

2-wire cable temperature sensors for pocket mounting

tech preview
  • Pt100 or Pt500 sensors
  • 2-wire connection with 2.5 m fixed cable
  • Approvals according to Directive 2004/22/EC (MID)
  • Approvals according to PTB K7.2 (cold measurement / combined cold and heat measurement)

Temperature sensors DS/PSC

2-wire cable temperature sensors for direct immersion or immersion in a thermowell

tech preview
  • DN125…250, PN16
  • TFluid = 0 – 80 °C
  • No moving parts
  • Low pressure loss
  • Approval: EN 1434 and PTB K7.2

AMFLO® MAG Basic

Electromagnetic compact flowmeter with integrated electronics for energy measurement
in industrial and commercial buildings

Data Collection

Data collection for thermal energy applications

AMBILL® derago

Mobile meter reading

tech preview
  • Wireless receiver and software in accordance wM-Bus/OMS EN 13757-4
  • Device range of up to 100 m

AMBILL® easy reader

Reading wireless meters

tech preview
  • Innovative WALK-BY & DRIVE-BY reading of transmitting heating and cooling counters as well as water and gas meters.
  • Broad support of measuring devices from different manufacturers by using the open communication standard OMS.
  • AMBILL® smart Suite 2 fulfils specific requirements of energy supply companies as well as contracted meter reading companies.
  • It collects automatically all data relevant for billing from all meters.
  • AMBILL® smart Suite 2 combines three tools in one package: Smart Read, Smart Param, Smart Scan

AMBILL® smart suite 2

Meter reading as simple as that

AMBILL® derago

Mobile meter reading

tech preview
  • Innovative WALK-BY & DRIVE-BY reading of transmitting heating and cooling counters as well as water and gas meters.
  • Broad support of measuring devices from different manufacturers by using the open communication standard OMS.
  • AMBILL® smart Suite 2 fulfils specific requirements of energy supply companies as well as contracted meter reading companies.
  • It collects automatically all data relevant for billing from all meters.
  • AMBILL® smart Suite 2 combines three tools in one package: Smart Read, Smart Param, Smart Scan

AMBILL® smart suite 2

Meter reading as simple as that

tech preview
  • Fully web based solution (Application Service Provider Solution or local installation)
  • Fully automatic process – from meter reading to billing (paper or email)
  • Consumption based billing
  • Interface to automatic meter reading solutions
  • Interface to accounting systems

AMBILL® easy bill

Web based facility billing system

tech preview
  • Transformation from wireless M-Bus (EN 13757-4 / OMS) to wired M-Bus (EN 13757-3)
  • M-Bus output to allow direct connection to a central office
  • Internal receiver aerial

AMBILL® smart link

Wireless M-Bus Converter

tech preview
  • Remote meter reading for specified meter data
  • Graphical display of load profiles
  • Export of meter data to Edifact, MSCONS, ASCII or Excel format
  • Meter reading via : M-Bus, LONWorks, CL0 (CS), Radio
  • Transmission via : Telephone or GSM modem, Ethernet / Internet, RS232, Infrared interface, Mobile data recording (PDA)

AMBUS® Gate

Energy data management system for automated remote meter reading of electricity, gas, water and heat meters

tech preview
  • Data logger
  • Load profiles and reset values for each new month
  • Configuration and querying of measurement values directly within the device or via M-Bus
  • Complete configuration through M-Bus
  • M-Bus and RS232C interface

AMBUS® IC-M12

Pulse storage module

tech preview
  • Pulse collector with M-Bus interface
  • Signal input with M-Bus interface
  • External power supply 12…18 V AC or 12…24 V DC
  • Configuration using AMBUS® Win software

AMBUS® IS

Pulse collector

tech preview
  • M-Bus centre with integrated web server
  • For 20, 60, 120 or 250 M-Bus meters
  • Data logger with plug-in data memory
  • 10/100 Base Ethernet
  • Transparent access to M-Bus

AMBUS® Link

Intelligent M-Bus data center for configuring, operating and monitoring M-Bus systems

tech preview
  • Remote reading, M-Bus power supply and voltage converter for up to 20 or 60 meters
  • Integrated 230 V mains supply
  • For all meters according to EN1434-3
  • Autonomous M-Bus remote reading unit
  • Automatic data logger

AMBUS® Log Serie

M-Bus data logger for up to 60 M-Bus devices

tech preview
  • M-Bus data centre with integrated web server
  • Integrated level converter for up to 250 M-Bus users
  • LCD touch screen with plain text display
  • Robust, tested casing for any application
  • Optional data logger with slot-in memory card (Compact Flash)

AMBUS® Net

M-Bus data center with integrated web server

tech preview
  • Compact level converter for 20 or 60 meters
  • Opto-electronic interface, RS-232 or RS-485
  • Transmission rate up to 9600 baud
  • Protection against short circuits and overvoltages
  • European standard EN1434

AMBUS® Port

M-Bus level converter

tech preview
  • Integrated power supply for connected meters
  • Up to 250 M-Bus meters for each AMBUS® level converter
  • Data communication via RS 232, RS 485 and M-Bus repeater input
  • Simple M-Bus installation with 4-wire cable

AMBUS® ZS

Signal-converter

Data Integration

Data integration for thermal energy applications

AMBILL® derago

Mobile meter reading

tech preview
  • Fully web based solution (Application Service Provider Solution or local installation)
  • Fully automatic process – from meter reading to billing (paper or email)
  • Consumption based billing
  • Interface to automatic meter reading solutions
  • Interface to accounting systems

AMBILL® easy bill

Web based facility billing system

tech preview
  • Wireless receiver and software in accordance wM-Bus/OMS EN 13757-4
  • Device range of up to 100 m

AMBILL® easy reader

Reading wireless meters

tech preview
  • Innovative WALK-BY & DRIVE-BY reading of transmitting heating and cooling counters as well as water and gas meters.
  • Broad support of measuring devices from different manufacturers by using the open communication standard OMS.
  • AMBILL® smart Suite 2 fulfils specific requirements of energy supply companies as well as contracted meter reading companies.
  • It collects automatically all data relevant for billing from all meters.
  • AMBILL® smart Suite 2 combines three tools in one package: Smart Read, Smart Param, Smart Scan

AMBILL® smart suite 2

Meter reading as simple as that

tech preview
  • Remote meter reading for specified meter data
  • Graphical display of load profiles
  • Export of meter data to Edifact, MSCONS, ASCII or Excel format
  • Meter reading via : M-Bus, LONWorks, CL0 (CS), Radio
  • Transmission via : Telephone or GSM modem, Ethernet / Internet, RS232, Infrared interface, Mobile data recording (PDA)

AMBUS® Gate

Energy data management system for automated remote meter reading of electricity, gas, water and heat meters

AMBILL® derago

Mobile meter reading

tech preview
  • Fully web based solution (Application Service Provider Solution or local installation)
  • Fully automatic process – from meter reading to billing (paper or email)
  • Consumption based billing
  • Interface to automatic meter reading solutions
  • Interface to accounting systems

AMBILL® easy bill

Web based facility billing system

tech preview
  • Innovative WALK-BY & DRIVE-BY reading of transmitting heating and cooling counters as well as water and gas meters.
  • Broad support of measuring devices from different manufacturers by using the open communication standard OMS.
  • AMBILL® smart Suite 2 fulfils specific requirements of energy supply companies as well as contracted meter reading companies.
  • It collects automatically all data relevant for billing from all meters.
  • AMBILL® smart Suite 2 combines three tools in one package: Smart Read, Smart Param, Smart Scan

AMBILL® smart suite 2

Meter reading as simple as that

tech preview
  • Remote meter reading for specified meter data
  • Graphical display of load profiles
  • Export of meter data to Edifact, MSCONS, ASCII or Excel format
  • Meter reading via : M-Bus, LONWorks, CL0 (CS), Radio
  • Transmission via : Telephone or GSM modem, Ethernet / Internet, RS232, Infrared interface, Mobile data recording (PDA)

AMBUS® Gate

Energy data management system for automated remote meter reading of electricity, gas, water and heat meters

Other solutions